GDYZ-301A Zinc Oxide Surge Arrester Tester

GDYZ-301A Zinc Oxide Surge Arrester Tester

Brief Description:

GDYZ-301A Automatic Zinc Oxide Surge Arrester Tester contains below three functions:

Resistive current test

Current meter calibration of monitor

Counter action test of monitor


Product Detail

Product Tags

It is the special equipment of testing zinc oxide electric performance. The instrument can accurately and stably measure the arrester resistive current and the monitor counter action parameters while the equipment is running. It can also check the monitor ammeter. 

Features

8inch color LCD touch screen, high speed thermal printer.
The measurement data of wire and wireless is the same.
Wireless sampling, with long distance.
A. Wired: indoor use, or on-site where the PT sampling wiring cabinet is near with tested lightning arrester.
B. Wireless: outdoor use, or on-site where the PT sampling wiring cabinet is far from tested lightning arrester, wireless distance is up to 1000M.
Three-phase can be measured at the same time. The resistive current of 3channels can be measured at the same time, meanwhile, there are two anti-interference modes: 1) no interference: the interphase angle cannot be calculated and corrected automatically under this mode; 2) With interference: the interphase interference angle can be calculated and corrected. Only one time connection to finish measurement of ABC phase.
Built-in high capacity Li-battery, suitable for no power supply field.

Technical Parameters
Use condition -20℃- 50℃ RH<80%
Charging power supply AC 220V±10%
Input range of PT reference voltage 0-300V
Input resistance of voltage channel 150kΩ(with fuse)
Measuring accuracy of PT reference voltage ±(2% of the reading+0.5V)
Measuring range of current input 0-10mA
Measurement accuracy of current fundamental ±(2% of the reading+5μA)
Measurement accuracy of current harmonic ±(5% of the reading+10μA)
Input resistance of current channel ≤1Ω
Action times of monitor 0~99times
8/20μS impulse current ≥50Ap
Calibration range of current meter 0-10mA
Calibration accuracy of current meter ±(2% of the reading+5μA)
Measurement resolution Voltage 0.001V
Current 0.001mA
Angle 0.001°
Battery working time Main unit 8hours, voltage sampling box 12hours
Wireless transmission distance 1000meters and above(empty and unobstructed)
Dimension of main unit 320×270×140mm
Handheld collection probe 180×120×80mm
Weight of main unit 4kg(without accessories)
Accessories

Main unit

1piece

Sampling unit

1piece

Wireless communication unit

1piece

Measurement cable of 3-phase resistive current

1piece

Sampling cable of 3-phase voltage

1piece

Output cable of current meter calibration

1piece

Ground cable

1piece

Power cord

1piece

Charger

1piece

Fuse

3pcs

Print paper

1roll

Alligator Clip

8pcs

Test report

1piece

Users guide

1piece


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us